Ethernet Configuration

All you need to know about Modem configuration for Ethernet with TotaLite
 

Ports

 

TotaLite only makes outbound connections — no inbound internet-facing port is required. Your firewall needs to allow the following outbound traffic:

 

Port

Destination

Purpose

UDP 67/68

Local DHCP server

Address acquisition

UDP 53

DNS server (via DHCP)

Hostname resolution

UDP 5684

lwm2m-connect

Device management

TCP 443

Amazon S3

Uploading measurements

UDEP 123

ntp.uio.no, time.google.com

Time sync

TCP 80

Firmware host

Firmware download

UDP 5683

Firmware host

Firmware download (CoAP)

 

If you integrate directly with the sensor's local HTTP API (port 2080), note that some operations — acknowledgements, storage info, image retrieval — can take up to 120 seconds. The API doesn't enforce a response deadline, so set your own client-side timeout with margin above 120 seconds.

 

Bandwidth

 

Internet providers measure speed in either MB/s (megabytes) or Mb/s (megabits) — a factor of 8 difference. Confirm which one your provider quotes before sizing your connection.

 

Minimum required speed depends on your measurement interval (MS, in seconds):

  • MB/s: 1.4 / MS
  • Mb/s: 11.2 / MS

Example, 5-minute interval (300 seconds):

  • 1.4 / 300 = 0.0047 MB/s
  • 11.2 / 300 = 0.037 Mb/s

 

NOTE: The connection must be stable, not just fast. The device reboots on connection failure, so an unstable high-speed connection isn't sufficient. Latency also matters: keep round-trip time under 2 seconds to avoid firmware download retransmissions.